File(s) | Type | Description | Action |
---|---|---|---|
sed_flux_dic_totalk.csv (50.02 KB) | Comma Separated Values (.csv) | Sediment flux of DIC and Total Alkalinity | Download |
These data include the measurements of dissolved inorganic carbon (DIC) and total alkalinity (TA) fluxes from sediment incubation experiments at several sites on the Louisiana shelf. Data were collected during four cruises in 2017 and 2018. Cruises were conducted aboard the R/V Pelican in April (PE17-18), July (PE18-02), and September-October (PE18-11) of 2017 and January of 2018 (PE18-19). The study domain included the Louisiana and Texas continental shelf from the Mississippi River Bird's Foot...
Show moreAt each site during the R/V Pelican cruises, a box corer was used to collect surface sediment. The box core was subsampled in triplicate using 40 cm acrylic tubes that were pushed into the sediment to refusal, i.e. 20-30 cm. Cores were extracted in the acrylic tubes, capped on the bottom with an acrylic cap and o-ring, and submerged in a dark incubator filled with bottom water collected at the site. Each core was carefully filled with in situ near bottom water with minimum disturbance to the sediment-water interface and closed to ensure no visible headspace or air bubbles at the top. The submerged cores were allowed to equilibrate with the water in the incubator for 12 hours. A control was included that was an acrylic liner filled with bottom water only. Following this equilibration step, the cores were capped on their tops with an acrylic cap and o-ring. The top caps contained two sampling ports that were opened to collect water samples from the water overlying the sediments in the core tubes. The overlying water was mixed by a slowly turning magnetic stir bar suspended from the top cap. All cores were attached to a reservoir containing bottom water for gravity driven replenishment of water inside the core tubes during sampling. After capping, sampling commenced.
Samples for DIC were taken every 4-8 hours for up to 23 hours (4-6 time points) from the four cores, i.e. one control core with bottom water only (identified as ‘Control’) and three cores with sediments and bottom water (identified as ‘Rep1’, ‘Rep2’, and ‘Rep3’). Dissolved inorganic carbon (DIC) and total alkalinity (TA) concentrations were analyzed in each sample by Wei Jun Cai’s lab at the University of Delaware. For DIC, 1 ml of water sample was measured in triplicate with an infrared CO2 detector-based DIC analyzer (AS-C3 Apollo Scitech). For TA, a 25 ml water sample was measured in duplicate with the open-cell Gran titration method using a temperature-controlled, semi-automated titrator (AS-ALK2 Apollo Scitech). Certified Reference Materials provided by A. G. Dickson, Scripps Institution of Oceanography, were analyzed for DIC and TA for quality control.
Detailed methods are provided in Wang et al. (2020) and Lehrter et al. (2012).
Problem report: Data for a few time points are missing due to lost or broken sample containers. For 1801 C6, there is missing data, so assumed depths are presented based on the depths similar to the last sampling on cruise 1710 C6-2.
Lehrter, J., Fung, M., Hagemeyer, A. (2023) Dissolved inorganic carbon and total alkalinity fluxes from sediment incubation experiments during four R/V Pelican cruises to the Louisiana shelf in 2017 and 2018. Biological and Chemical Oceanography Data Management Office (BCO-DMO). (Version 1) Version Date 2023-05-30 [if applicable, indicate subset used]. doi:10.26008/1912/bco-dmo.896598.1 [access date]
Terms of Use
This dataset is licensed under Creative Commons Attribution 4.0.
If you wish to use this dataset, it is highly recommended that you contact the original principal investigators (PI). Should the relevant PI be unavailable, please contact BCO-DMO (info@bco-dmo.org) for additional guidance. For general guidance please see the BCO-DMO Terms of Use document.