Dataset: Aerosol lead (Pb) and Pb isotopes from Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1815) on R/V Roger Revelle from Oct-Nov 2018

Release Date:2025-02-01Preliminary and in progressVersion 1 (2024-08-02)Dataset Type:Cruise Results

Principal Investigator: Edward A. Boyle (Massachusetts Institute of Technology)

BCO-DMO Data Manager: Shannon Rauch (Woods Hole Oceanographic Institution)


Program: U.S. GEOTRACES (U.S. GEOTRACES)

Project: US GEOTRACES Pacific Meridional Transect (GP15) (U.S. GEOTRACES PMT)

Project: Collaborative Research: US GEOTRACES PMT: Pb and Cr isotopes (PMT Pb and Cr)

The Pb sub-samples were collected by the group of Dr. Clifton Buck using the high-volume sampling system described by Morton et al. (2013). The sampling method and filter preparation are identical to that described in the "GEOTRACES Cookbook" (Cutter et al., 2014). The samples were sealed in clean plastic and shipped to MIT for analysis.

Pb isotopic measurements by the isotope dilution method were carried out using a 205Pb tracer solution (ET535) that was prepared and calibrated as part of the EARTHTIME project (Condon et al., 2015; McLean et al., 2015). These measurements were carried out by undergraduate student Avery Wang and Research Scientist Jahander Ramezani.

Filters were leached inside a Pb clean fluorocarbon vial with 0.1 M nitric acid at 100° Celsius for 24 hours. The solutions were taken to dryness, and then dissolved in 400 microliters (µL) of 1.1M HBr. Samples were purified by anion exchange chromatography on Eichrom AG-1x8 resin (cleaned by three batch rinses with 6N trace metal clean HCl for a ~12 hours on a shaker table, followed by multiple washes with distilled water until the pH of the solution was above 4.5; resin was stored at room temperature in the dark until use) using 1.1M HBr and 2M HCl to wash out impurities prior to collecting the sample with 6M HCl. Eluted samples were analyzed on a IsotopX Thermal Ionization Mass Spectrometer using repeated runs of standard NBS981 to account for mass fractionation.


Related Datasets

No Related Datasets

Related Publications

Methods

Baker, J., Peate, D., Waight, T., & Meyzen, C. (2004). Pb isotopic analysis of standards and samples using a 207Pb–204Pb double spike and thallium to correct for mass bias with a double-focusing MC-ICP-MS. Chemical Geology, 211(3-4), 275–303. doi:10.1016/j.chemgeo.2004.06.030
Methods

Condon, D. J., Schoene, B., McLean, N. M., Bowring, S. A., & Parrish, R. R. (2015). Metrology and traceability of U–Pb isotope dilution geochronology (EARTHTIME Tracer Calibration Part I). Geochimica et Cosmochimica Acta, 164, 464–480. https://doi.org/10.1016/j.gca.2015.05.026
Methods

Cutter, G.A., Andersson, P., Codispoti, L., Croot, P., Francois, R., Lohan, M., Obata, H., van der Loeff, M. R. (2014) Sampling and Sample-Handing Protocols for GEOTRACES Cruises (cookbook) Version 2.0; December 2014.
Methods

McLean, N. M., Condon, D. J., Schoene, B., & Bowring, S. A. (2015). Evaluating uncertainties in the calibration of isotopic reference materials and multi-element isotopic tracers (EARTHTIME Tracer Calibration Part II). Geochimica et Cosmochimica Acta, 164, 481–501. https://doi.org/10.1016/j.gca.2015.02.040
Methods

Morton, P. L., Landing, W. M., Hsu, S.-C., Milne, A., Aguilar-Islas, A. M., Baker, A. R., … Zamora, L. M. (2013). Methods for the sampling and analysis of marine aerosols: results from the 2008 GEOTRACES aerosol intercalibration experiment. Limnology and Oceanography: Methods, 11(2), 62–78. doi:10.4319/lom.2013.11.62