Instrument: Hewlett Packard 5890 Series II gas chromatograph

Acronym: HP 5890 Series II GC
External Identifier: skos:exactMatch: https://vocab.nerc.ac.uk/collection/L22/current/TOOL0558/

Description

A gas chromatograph that separates and analyses compounds that do not degrade or decompose in the gas phase. The sample is dissolved in a solvent and vaporised in the instrument. A chemically inert gas, (e.g. helium or nitrogen) carries the vaporised analyte through a stationary phase which is coated inside the capillary column that is maintained at an elevated temperature. The analyte mixture separates on the stationary phase leading to chromatographic separation of the molecules. The HP 5890 Series II is completely customisable depending on the application, with choices of inlets, columns, detectors, sampling systems, flow and pressure control components. Optional detectors include Flame Ionization Detector (FID), Nitrogen-Phosphorus Detector (NPD), Electron Capture Detector (ECD), Thermal Conductivity Detector (TCD), Photoionisation Detector (PID), Flame Photometric Detector (FPD) and mass spectrometer. The instrument was originally manufactured by Hewlett Packard (HP), but part of this business was sold to Agilent Technologies in 1999. This model is no longer in production.


Dataset NamePI-Supplied DescriptionPI-Supplied Name
Porewater geochemistry, including methane, CO2, sulfate, and sulfide from Guaymas Basin hydrothermal sediments collected on R/V Atlantis cruise AT15-56 in Nov-Dec 2009Stable isotopic compositions of the methane samples were measured via gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) on a Finnigan MAT 252 Isotope Ratio Mass Spectrometer, using a HP 5890 Series II Gas Chromatograph with a HP Plot Q column (30 m length, 0.32 mm ID, 20 um film thickness) and a 30 degree C isothermal temperature profile. Stable isotopic values and concentrations of DIC were analyzed via coupled GC (Hewlett Packard 5890) and Isotope Ratio Mass Spectrometer (Finnigan MAT 252). HP 5890 Series II Gas Chromatograph
Particulate Acid-Volatile Sulfide (pAVS) and Chromium Reducible Sulfide (pCRS) from Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from September to October 2018Hewlett Packard (HP) 5890 Series II gas chromatograph
Particulate Acid-Volatile Sulfide (pAVS) and Chromium Reducible Sulfide (pCRS) from Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1815) on R/V Roger Revelle from Oct to Nov 2018Hewlett Packard (HP) 5890 Series II gas chromatograph
Total dissolved sulfide (TDS) and carbonyl sulfide (OCS) from Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from September to October 2018Hewlett Packard (HP) 5890 Series II gas chromatograph
Total dissolved sulfide (TDS) and carbonyl sulfide (OCS) from Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1815) conducted on R/V Roger Revelle from October to November 2018Hewlett Packard (HP) 5890 Series II gas chromatograph