Instrument: Lachat QuikChem 8000 flow injection analyzer and Ion Chromatography (IC) system

Acronym:
External Identifier: skos:exactMatch: http://vocab.nerc.ac.uk/collection/L22/current/TOOL0848/

Description

The Lachat QuikChem 8000 can operate flow injection analysis and ion chromatography simultaneously and independently on the same instrument platform. Instrument includes sampler, dilutor, sampling pump, electronics unit, and data station. Analysis takes 20-60 seconds, with a sample throughput of 60-120 samples per hour. Measurements are in the range of parts per trillion to parts per hundred.


Dataset NamePI-Supplied DescriptionPI-Supplied Name
Carbon and nitrogen data from kelp determined during seasonal global change experiments examining the effects of seasonal variation in light availability and nutrients on the response of three high-latitude kelp speciesAnalysis for dissolved inorganic nitrogen content as NOx (NO3 + NO2) and ammonium (NH4+) was done on a Lachat QuikChem 8000 Flow Injection Analyzer at the University of California Santa Cruz Marine Analytical Laboratory. Lachat QuikChem 8000 Flow Injection Analyzer
Dissolved trace metals and macronutrients from samples collected using GoFlo on R/V Melville MV1405 (IRN-BRU) cruise in the California Current System in July 2014Nutrients were analyzed with a Lachat QuickChem 8000 Flow Injection Analysis System. Lachat QuickChem 8000 Flow Injection Analysis System
Dissolved trace metals and macronutrients from samples collected using a tow-fish system on R/V Melville MV1405 (IRN-BRU) cruise in the California Current System in July 2014Nutrients were analyzed with a Lachat QuickChem 8000 Flow Injection Analysis System. Lachat QuickChem 8000 Flow Injection Analysis System
Results from feeding assays conducted as part of seasonal global change experiments examining the effects of seasonal variation in light availability and nutrients on the response of three high-latitude kelp speciesAnalysis for dissolved inorganic nitrogen content as NOx (NO3 + NO2) and ammonium (NH4+) was done on a Lachat QuikChem 8000 Flow Injection Analyzer at the University of California Santa Cruz Marine Analytical Laboratory. Lachat QuikChem 8000 Flow Injection Analyzer
Kelp growth data from seasonal global change experiments examining the effects of seasonal variation in light availability and nutrients on the response of three high-latitude kelp species Analysis for dissolved inorganic nitrogen content as NOx (NO3 + NO2) and ammonium (NH4+) was done on a Lachat QuikChem 8000 Flow Injection Analyzer at the University of California Santa Cruz Marine Analytical Laboratory. Lachat QuikChem 8000 Flow Injection Analyzer
Measured and calculated geochemistry values and uncertainty for water samples taken from the water column of Celestun Lagoon, Yucatan, Mexico in May of 2015Lachat QuikChem 8000
CTD bottle data matched to dissolved, inorganic nutrient concentrations and to stable isotope measurements of particulate nitrogen and carbon rom R/V Melville cruise MV1110 in the Western Tropical North Atlantic in 2011Lachat Quikchem 8000 Series for dissolved, inorganic nutrients Lachat Quikchem 8000 Series
Underway nutrient and particle data from R/V Melville cruise MV1110 in the Western Tropical North Atlantic in 2011Lachat Quikchem 8000 Series for dissolved, inorganic nutrients Lachat Quikchem 8000 Series
In situ tracer injection experiment conducted with 15N-labeled ammonium in a shallow, sandy subterranean estuary in Gloucester Point, USA in August 2019. Ion Chromatograph, ThermoFisher Scientific; Lachat QuikChem 8000 automated ion analyzer Lachat In- struments, Milwaukee, WI, USA; detection limits for NO3−, NH4+, and PO43− are 0.20, 0.36, and 0.16 μM, respectively. Gas bench isotope ratio mass spectrometer (IRMS) Delta V Plus, Thermo Fisher Scientific, Waltham, MA. Ion Chromatograph, ThermoFisher Scientific; Lachat QuikChem 8000 automated ion analyzer Lachat In- struments
Sediment Nitrification Incubation data of a subterrarnian estuary core take in July 2020 in Gloucester Point, Virginia Lachat QuikChem 8000 automated ion analyzer Lachat In- struments, Milwaukee, WI, USA; detection limits for NO3−, NH4+, and PO43− are 0.20, 0.36, and 0.16 μM, respectively. Lachat QuikChem 8000 automated ion analyzer