Instruments separating gases, volatile substances or substances dissolved in a volatile solvent by transporting an inert gas through a column packed with a sorbent to a detector for assay by a mass spectrometer.
Dataset Name | PI-Supplied Description | PI-Supplied Name |
---|---|---|
Analyses of nitrate reference solutions in 18O-labeled water with the denitrifier method (Biological Nitrogen Isotope Fractionation project) | Delta V Advantage continuous flow gas chromatograph isotope ratio mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) interfaced with a modified Thermo Fisher Scientific Gas Bench sample preparation device fronted by dual cold traps (Casciotti et al., 2002) and a GC Pal autosampler (CTC Analytics, Zwingen, Switzerland) - to measure N and O isotope ratio of nitrate using the denitrified method. | Delta V Advantage continuous flow gas chromatograph isotope ratio mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) |
Water column properties and carbon geochemistry from R/V Blackbeard and R/V Neil Armstrong cruises in coastal North Carolina in 2018 and 2019 | Shimadzu QP2010S | |
Atlantic sediment polycyclic aromatic hydrocarbon (PAH) concentrations from samples collected using a multi-corer and box corer from multiple cruises throughout the Atlantic between 1994 and 2010 | Agilent 6890 Series gas chromatograph coupled to a 5973 Mass Selection Detector (GC-MS) | |
Volume effects on blanks originating from the bacterial concentrates, equilibration with atmospheric N2O, and NO3- contamination of the water into which the standards were diluted from 2017-2020 (Biological Nitrogen Isotope Fractionation project) | Delta V Advantage continuous flow gas chromatograph isotope ratio mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) interfaced with a modified Thermo Fisher Scientific Gas Bench sample preparation device fronted by dual cold traps (Casciotti et al., 2002) and a GC Pal autosampler (CTC Analytics, Zwingen, Switzerland) - to measure N and O isotope ratio of nitrate using the denitrified method. | isotope ratio mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) |
CSIA-AA comparison between live polyps and outer proteinaceous skeletal material in three taxons of North Pacific deep-sea corals | Gas Chromatography Combustion Isotope Ratio Mass Spectrometry (GC/C/IRMS). For AA δ13C analyses, the derivatized AAs were injected in split mode at 250°C and separated on a DB-5 column (50 m x 0.5 mm inner diameter; 0.25 mm film thickness; Agilent Technologies, Santa Clara, California, USA) in a Thermo Trace Ultra gas chromatograph (GC) at the University of California, Santa Cruz. The separated AA peaks were analyzed on a Finnegan MAT DeltaPlus XL IRMS interfaced to the GC through a GC-C III combustion furnace (960°C) and reduction furnace (630°C). For AA δ15N analyses, the derivatized AAs were injected in splitless mode at 250 °C and separated on a BPX5 column (60 m x 0.32 mm inner diameter, 1.0 mm film thickness; SGE Analytical Science, Austin, Texas, USA) in the same CG-C-IRMS interfaced through a combustion furnace (980°C), reduction furnace (650°C), and a liquid nitrogen trap. | GC/C/IRMS |
Ambient concentrations of acetate, glycerol, and mannitol measured from samples collected during R/V Endeavor cruise EN616 in the northwest Atlantic in July 2018 | Analysis was carried out on a Shimadzu GCMS-QP2010 gas chromatograph-mass spectrometer (GC-MS) equipped with a Shimadzu SHRXI-5MS column | Shimadzu GCMS-QP2010 gas chromatograph-mass spectrometer |
Hurricane Harvey impacts on biogeochemistry of sediments assessed using samples collected in Mission-Aransas Estuary in south Texas from June 2017 to March 2019 | The Shimadzu QP2010 plus GC-MS used for this study is equipped with a RXi-1MS capillary column (20 mÅ~0.18 mm i.d., film thickness 0.18 μ m), with helium as the carrier gas at a flow rate of 0.8 mL min−1, using a selective ion monitoring mode to detect PAHs. | GC-MS, Shimadzu QP2010 plus |
Chemical analyses of size-fractionated particle samples collected during the BIOS-SCOPE cruise AE1819 in the Sargasso Sea in July 2018 | GC-MS,GC-IRMS (gas chromatography-isotope ratio mass spectrometry equipped with a TG-5MS column) | GC-MS,GC-IRMS |
Volume-dependent offsets in NO3- N and O isotope ratios of reference materials (Biological Nitrogen Isotope Fractionation project) | Delta V Advantage continuous flow gas chromatograph isotope ratio mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) interfaced with a modified Thermo Fisher Scientific Gas Bench sample preparation device fronted by dual cold traps (Casciotti et al., 2002) and a GC Pal autosampler (CTC Analytics, Zwingen, Switzerland) - to measure N and O isotope ratio of nitrate using the denitrified method. | Delta V Advantage continuous flow gas chromatograph isotope ratio mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) |
Effects of sample volume on N2O recovery and isotopic analysis (Biological Nitrogen Isotope Fractionation project) | Delta V Advantage and MAT253 continuous flow gas chromatograph isotope ratio mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) interfaced with a modified Thermo Fisher Scientific Gas Bench sample preparation device fronted by dual cold traps (Casciotti et al., 2002) and a GC Pal autosampler (CTC Analytics, Zwingen, Switzerland) - to measure N and O isotope ratio of nitrate using the denitrified method. | Delta V Advantage and MAT253 continuous flow gas chromatograph isotope ratio mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) |
Carbon isotopic compositions and fractionation factors of M. jannaschii in high and low hydrogen (H2) environments | For or identification and abundance of carbon isotopes. Agilent Technologies 5975 inert XL Mass Selective Detector after separation on an Agilent J&W GC HP-5MS UI capillary column (30 m × 0.25 mm i.d., 0.25 µm film thickness, P/N 19091S – 433UIE) | Gas Chromatograph Mass Spectrometer |
Carbon isotopic compositions and fractionation factors of M. jannaschii in high and low hydrogen (H2) environments | For measuring isotopic composition of biomarkers, including amino acid and lipids: Thermo Scientific Trace 1310 Gas Chromatograph-IsolinkII-Delta V Isotope Ratio Mass Spectrometer equipped with an Agilent DB-5 fused silica column (30 m × 0.25 mm i.d., 0.25 µm film thickness) and a Gerstel CIS – 6 inlet. | Thermo Scientific Trace 1310 Gas Chromatograph-IsolinkII-Delta V Isotope Ratio Mass Spectrometer |
Nitrogen isotope fractionation for ammonium assimilation by marine phytoplankton (Biological Nitrogen Isotope Fractionation project) | Used to analyze N isotopes of nitrous oxide gas derived from chemical oxidation of NH4+ using the hypobromite-azide method (Zhang et al. 2007), with calibrations achieved using NH4+ reference materials IAEA-N1 and IAEA-N2. | Thermo Delta V gas chromatograph isotope ratio mass spectrometer (GC-IRMS) |