Instrument: Flow Injection Analyzer

Acronym: FIA
External Identifier: skos:broadMatch: http://vocab.nerc.ac.uk/collection/L05/current/LAB36/

Description

An instrument that performs flow injection analysis. Flow injection analysis (FIA) is an approach to chemical analysis that is accomplished by injecting a plug of sample into a flowing carrier stream. FIA is an automated method in which a sample is injected into a continuous flow of a carrier solution that mixes with other continuously flowing solutions before reaching a detector. Precision is dramatically increased when FIA is used instead of manual injections and as a result very specific FIA systems have been developed for a wide array of analytical techniques.

Dataset NamePI-Supplied DescriptionPI-Supplied Name
32Si and 14C production data (experimental) from EXPORTS cruise RR1813 on R/V Roger Revelle in the Subarctic North Pacific near Station PAPA from August to September 2018Lachat Instruments QuikChem 8500 Series 2 anayzer
32Si data from EXPORTS cruise RR1813 on R/V Roger Revelle in the Subarctic North Pacific near Station PAPA from August to September 2018Lachat Instruments QuikChem 8500 Series 2 anayzer
Nitrogen fixation rates from samples collected in the Chukchi Sea, Arctic Ocean near Barrow, Alaska in August of 2011 (ArcticNITRO project)Nitrate and phosphate were measured using a Lachat QuikChem 8500 autoanalyzer.   Lachat QuickChem 8500 autoanalyzer
Concentrations of trace metals and dissolved macronutrients and CTD sensor data from four cruises in the Bermuda Atlantic Time-series Study (BATS) region in March, May, August and November 2019Concentrations of DAl were determined in the acidified sewater filtrate using flow injection analysis with fluorometric detection. Fluorescence detector for flow-injection analysis: RF-10AXL HPLC detector (Shimadzu).
Porewater geochemistry of sediments collected Fall 2019 in the Santa Barbara Basin using ROV Jason during R/V Atlantis cruise AT42-19Porewater Dissolved Inorganic Carbon was determined using a flow injection system (Hall & Aller 1992). flow injection system
Iodine speciation and superoxide concentration depth profile value from iodine radiotracer incubation experiments conducted on the R/V Atlantic Explorer cruise AE1825 with samples collected at BATS and Hydrostation S in September of 2018Superoxide concentrations were measured using a FeLume Mini (Waterville Analytical) and the O2−-specific chemiluminescent probe methyl cypridina luciferin analog. FeLume Mini (Waterville Analytical)
Benthic flux data from sediment cores collected in the York River Estuary, VA in 2020Nutrient analyses (NO₃, NO₂, NH₄) were performed with a Lachat QuikChem 8000 automated ion analyzer (Lachat Instruments, Milwaukee, WI, USA). Lachat QuikChem 8000
Benthic macroalgal and water column carbon uptake rates in an experimental chamber, Maunalua, O’ahu, Hawai’i, 2015-2016Seal Analytical Segmented Flow Injection AutoAnalyzer AA3HR
Biogeochemical measurements from R/V Blue Heron BH10-01, BH10-06, BH10-13, BH10-22, BH09-SINC1 in the Lake Superior from 2009 to 2010 (SINC project) Lachat flow injection analyzer Detailed Acquisition and Processing Metadata for All Parameters Metadata generated from original file "2010 Great Lakes Biogeochem Data.xlsx, Sheet: Metadata" contributed by Bob Sterner See Individual Deployments/Data Info for cruise specific sampling notes. Lachat Flow Injection Analyzer
BioGeoChemistry from R/V Blue Heron BH07-09, BH07-17, BH07-19, BH08-01, BH08-11, BH08-19 in Lake Superior from 2007-2008 (CARGO project)Lachat flow injection analyzer Detailed Acquisition and Processing Metadata for All Parameters Metadata generated from original file "2007 Great Lakes Biogeochem Data.xlsx, Sheet: Metadata" contributed by Bob Sterner See Individual Deployments/Data Info for cruise specific sampling notes Lachat Flow Injection Analyzer
Biogeochemical and microbial parameters collected during spatial surveys on a coral reef at Mo'orea's North Shore (French Polynesia) in September 2017, May 2019, and April 2022Seal AA3 Segmented Flow Injection Autoanalyzer
BIOS-SCOPE survey biogeochemical data as collected on Atlantic Explorer cruises (AE1614, AE1712, AE1819, AE1916) from 2016 through 2019 Lachat QuikChem 8500 series 2 was used to measure nitrate, nitrite, ortho-phosphate, ammonium, and silicate by flow injection analysis Lachat QuikChem 8500 series 2
Samples for nitrite and nitrate concentration measurements were syringe-filtered (0.22 µm, Sterivex) and stored at −20°C before concentrations were determined by Cd reduction coupled to colorimetric detection via the Griess assay on a Lachat autoanalyzer.  QuikChem 8500 Series 2 Flow Injection System (Lachat Instruments)
Concentrations of colored dissolved organic matter, dissolved organic carbon, and total phosphorous from experiments conducted at the University of Hawaii, Manoa in 2015 (Coral DOM2)Seal Analytical Segmented Flow Injection AutoAnalyzer AA3HR
Biogeochemical data collected from porewater profiles within a shallow, sandy subterranean estuary (STE) in Virginia USA, from 2018 - 2020Lachat QuikChem 8000 automated ion analyzer Lachat In- struments, Milwaukee, WI, USA; detection limits for NO3−, NH4 +, and PO43− are 0.20, 0.36, and 0.16 μM, respectively automated ion analyzer
1A: Partitioning of carbon as a function of pCO2 and temperature during growth of Thalassiosira weissflogii from UCSB Marine Science Institute Passow Lab from 2009 to 2010 (OA - Effects of High CO2 project)Samples for dissolved inorganic nitrate, nitrite, phosphate and silicate were filtered through 0.2 µm filters and measured on a flow injection analyzer (Lachat Instruments Div., QuikChem 8000). Lachat Instruments Div., QuikChem 8000
2A: Partitioning of carbon as a function of pCO2 and temperature during growth of Dactyliosolen fragilissimus from U.C. Santa Barbara Marine Science Institute Passow Lab from 2009 to 2010 (OA - Effects of High CO2 project)Samples for dissolved inorganic nitrate, nitrite, phosphate and silicate were filtered through 0.2 µm filters and measured on a flow injection analyzer (Lachat Instruments Div., QuikChem 8000). Lachat Instruments Div., QuikChem 8000
Experiment with the diatom Chaetoceros sp. on the impact of temperature, light climate, and carbonate chemistry on TEP production and aggregation processes from May 2015 (OA - Effects of High CO2 project)Nutrient samples were measured on a flow injection analyzer (QuickChem 8000, Lachat Instruments, Zellweger Analytics) flow injection analyzer (QuickChem 8000, Lachat Instruments, Zellweger Analytics)
GenBank accession numbers for ammonia oxidizer genes collected on the R/V Endeavor (SQO-Delta) in the San Francisco Bay Delta during September and October 2007.Concentrations measured via QuikChem 8000 Flow Injection Analyzer QuikChem 8000
Potential nitrification rates and ammonia oxidizer gene abundances collected on R/V Endeavor (SQO-Delta) in the San Francisco Bay Delta during September and October 2007Concentrations measured via QuikChem 8000 Flow Injection Analyzer QuikChem 8000
Silica production rates and concentrations quantified using 32Si and PDMPO using samples from the R/V Point Sur cruise PS1312 along the Central California coast from June to July of 2013 (Diatom Group Si Prod project)University of California Santa Barbara Marine Science Institute’s Analytical Laboratory using flow injection techniques on a QuickChem 8000 analyzer (Lachat Instruments Division, Zellweger Analytics) as described in Brzezinski and Washburn (2011). Brzezinski, M. A., and L. Washburn.  2011.  Phytoplankton primary productivity in the Santa Barbara Channel: Effects of wind-driven upwelling and mesoscale eddies.  Journal of Geophysical Research Oceans, 116, C12013, doi:10.1029/2011JC007397. QuickChem 8000 analyzer
Discrete data on hydrography (from CTD casts) and chemical analyses of dissolved nutrients and organic carbon on the Louisiana-Texas shelf in the Gulf of Mexico from R/V Pelican cruise 28 September – 11 October 2017Water samples were analyzed for NO₃⁻ + NO₂⁻, NO₂⁻, PO₄³−, SiO₂, and NH₄⁺ using a Lachat Instruments QuikChem® FIA+ 8000 Series Automated Ion Analyzer with an ASX-400 Series XYZ autosampler. Lachat Instruments QuikChem® FIA+ 8000 Series Automated Ion Analyzer
Discrete data on hydrography (from CTD casts) and chemical analyses of dissolved nutrients and organic carbon on the Louisiana-Texas shelf in the Gulf of Mexico from R/V Acadiana cruise 18-21 September 2017Water samples were analyzed for NO₃⁻ + NO₂⁻, NO₂⁻, PO₄³−, SiO₂, and NH₄⁺ using a Lachat Instruments QuikChem® FIA+ 8000 Series Automated Ion Analyzer with an ASX-400 Series XYZ autosampler. Lachat Instruments QuikChem® FIA+ 8000 Series Automated Ion Analyzer
DOC and DON concentrations of waters collected from the North Pacific Subtropical Gyre and Central North AtlanticLachat QuickChem 8000 Flow Injection Analyzer
Measurements of Chlorophyll, NO2, NO3, PO4, Silicate, NH4, PIC, POC, PON, BSi from CTD casts on R/V Endeavor cruise EN616 in July 2018Lachat QuickChem 8000
Experimental and survey biogeochemical and microbial data from R/V Point Sur cruises PS1009 and PS1103 in the Santa Barbara Channel from 2010-2011 (SBDOM project, SBC LTER project)A flow injection autoanalyzer (Lachat QuikChem 8000) was used. flow injection autoanalyzer
Fall 2011 - Porewater SamplesPorewater samples collected for: NOx (Nitrate + Nitrite) Nitrite Orthophosphate Reactive Silicate Analytical Method: Flow Injection Autoanalyzer  Instrument: Lachat Instruments FIA+ 8000 Series  Method Reference(s): Lachat Instruments FIA 8000 Autoanalyzer Method 31-107-04-1-A Lachat Instruments FIA 8000 Autoanalyzer Method 31-115-01-1-H Lachat Instruments FIA 8000 Autoanalyzer Method 31-114-27-1-D Lachat Instruments FIA+ 8000 Series
Fall 2011 - Water Column SamplesPorewater samples collected for: NOx (Nitrate + Nitrite) Nitrite Orthophosphate Reactive Silicate Analytical Method: Flow Injection Autoanalyzer  Instrument: Lachat Instruments FIA+ 8000 Series  Method Reference(s): Lachat Instruments FIA 8000 Autoanalyzer Method 31-107-04-1-A Lachat Instruments FIA 8000 Autoanalyzer Method 31-115-01-1-H Lachat Instruments FIA 8000 Autoanalyzer Method 31-114-27-1-D Lachat Instruments FIA+ 8000 Series
Hydrologic data from field sampling sites in the Neuse River Estuary, Pamlico Sound, and Onslow Bay in the coastal North Atlantic, offshore from North Carolina, USA, in 2021 and 2022Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI, USA)
Summary geochemistry and radiotracer rates for 30 marine sediment cores covering eight sites and four geochemical regimesLachat Instruments FIA 8000 Autoanalyzer. Calibrated with standards made from NaNO2 dissolved in MQ (0-10 uM) Lachat FIA 8000 Autoanalyzer
Dissolved Fe(II) from the southbound leg of the US GEOTRACES Arctic cruise (HLY1502) on USCGC Healy from August to October 2015FeLume II Waterville Analytical
Shipboard FIA dissolved Al, Fe, and Mn from samples collected by GO-FLO bottles during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophometric detection (Rainin Dynamax UV-C). Major components of the scheme include a Rabbit peristaltic pump, a Dynamax FL-1 fluorometer, a Rainin A/D board, and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. FIA
Shipboard FIA dissolved Al, Fe, and Mn from samples collected by GO-FLO bottles during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. The spectrophotometric detection of the iron eluted from the column is achieved through its catalytic effect on the oxidation of N,N-dimethylp-phenylenediamine dihydrochloride (DPD) the oxidized product is measured at 514 nm. Flow injection for dFe DPD system with Rainin Dynamax Absorbance detector UV-C
Shipboard FIA dissolved Al, Fe, and Mn from samples collected by GO-FLO bottles during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Mn was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. Flow injection for dMn system with Rainin Dynamax Absorbance detector UV-C
Shipboard FIA dissolved Al, Fe, and Mn from melt pond samples collected during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophometric detection (Rainin Dynamax UV-C). Major components of the scheme include a Rabbit peristaltic pump, a Dynamax FL-1 fluorometer, a Rainin A/D board, and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. FIA
Shipboard FIA dissolved Al, Fe, and Mn from melt pond samples collected during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. The spectrophotometric detection of the iron eluted from the column is achieved through its catalytic effect on the oxidation of N,N-dimethylp-phenylenediamine dihydrochloride (DPD) the oxidized product is measured at 514 nm. Flow injection for dFe DPD system with Rainin Dynamax Absorbance detector UV-C
Shipboard FIA dissolved Al, Fe, and Mn from melt pond samples collected during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Mn was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. Flow injection for dMn system with Rainin Dynamax Absorbance detector UV-C
Shipboard FIA dissolved Al, Fe, and Mn from samples collected by pump during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. The spectrophotometric detection of the iron eluted from the column is achieved through its catalytic effect on the oxidation of N,N-dimethylp-phenylenediamine dihydrochloride (DPD) the oxidized product is measured at 514 nm. Flow injection for dFe DPD system with Rainin Dynamax Absorbance detector UV-C
Shipboard FIA dissolved Al, Fe, and Mn from samples collected by pump during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Mn was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. Flow injection for dMn system with Rainin Dynamax Absorbance detector UV-C
Shipboard FIA dissolved Al, Fe, and Mn from samples collected by pump during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophometric detection (Rainin Dynamax UV-C). Major components of the scheme include a Rabbit peristaltic pump, a Dynamax FL-1 fluorometer, a Rainin A/D board, and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. FIA
Shipboard FIA dissolved Al, Fe, and Mn from samples collected from ice floes using a pump during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophometric detection (Rainin Dynamax UV-C). Major components of the scheme include a Rabbit peristaltic pump, a Dynamax FL-1 fluorometer, a Rainin A/D board, and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. FIA
Shipboard FIA dissolved Al, Fe, and Mn from samples collected from ice floes using a pump during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. The spectrophotometric detection of the iron eluted from the column is achieved through its catalytic effect on the oxidation of N,N-dimethylp-phenylenediamine dihydrochloride (DPD) the oxidized product is measured at 514 nm. Flow injection for dFe DPD system with Rainin Dynamax Absorbance detector UV-C
Shipboard FIA dissolved Al, Fe, and Mn from samples collected from ice floes using a pump during USCGC Healy cruise HLY1502 (GN01) in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015Dissolved Mn was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. Flow injection for dMn system with Rainin Dynamax Absorbance detector UV-C
Size-fractionated major and minor particle composition and concentration from the US GEOTRACES Arctic cruise (HLY1502) on USCGC Healy from August to October 2015Used to analyze the following measured parameters: bSi; and the following derived parameters: OPAL Lachat QuikChem 8000 Flow Injection Analyzer
Shipboard FIA of Dissolved Al, Fe, and Mn from Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from September to October 2018Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. The spectrophotometric detection of the iron eluted from the column is achieved through its catalytic effect on the oxidation of N,N-dimethylp-phenylenediamine dihydrochloride (DPD) the oxidized product is measured at 514 nm. Flow injection for dFe DPD system with Rainin Dynamax Absorbance detector UV-C
Shipboard FIA of Dissolved Al, Fe, and Mn from Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from September to October 2018Dissolved Mn was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. Flow injection for dMn system with Rainin Dynamax Absorbance detector UV-C
Shipboard FIA of Dissolved Al, Fe, and Mn from Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from September to October 2018Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophometric detection (Rainin Dynamax UV-C). Major components of the scheme include a Rabbit peristaltic pump, a Dynamax FL-1 fluorometer, a Rainin A/D board, and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. Flow Injection Analysis scheme with spectrophometric detection
Shipboard FIA of Dissolved Al, Fe, and Mn from Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1815) on R/V Roger Revelle from October to November 2018Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophometric detection (Rainin Dynamax UV-C). Major components of the scheme include a Rabbit peristaltic pump, a Dynamax FL-1 fluorometer, a Rainin A/D board, and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. Flow Injection Analysis scheme with spectrophometric detection
Shipboard FIA of Dissolved Al, Fe, and Mn from Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1815) on R/V Roger Revelle from October to November 2018Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. The spectrophotometric detection of the iron eluted from the column is achieved through its catalytic effect on the oxidation of N,N-dimethylp-phenylenediamine dihydrochloride (DPD) the oxidized product is measured at 514 nm. Flow injection for dFe DPD system with Rainin Dynamax Absorbance detector UV-C
Shipboard FIA of Dissolved Al, Fe, and Mn from Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1815) on R/V Roger Revelle from October to November 2018Dissolved Mn was determined using a Flow Injection Analysis scheme with spectrophotometric detection (Rainin Dynamax UV-C). Major components were a Rabbit peristaltic pump, a Rainin Dynamax UV-C, a Rainin A/D board and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. Flow injection for dMn system with Rainin Dynamax Absorbance detector UV-C
Concentrations of dissolved aluminum (Al) in samples collected during the U.S. GEOTRACES EPZT cruise (R/V Thomas G. Thompson TN303) from October to December 2013flow injection analysis
Water-column dissolved iron (Fe) concentrations for major stations occupied during U.S. GEOTRACES EPZT cruise (R/V Thomas G. Thompson TN303) from October to December 2013; post-cruise analyses conducted at Old Dominion UniversityDissolved iron was determined by flow injection analysis (FIA) with colorimetric detection after in-line preconcentration on resin-immobilized 8-hydroxyquinoline.
Concentrations of dissolved manganese (Mn) in water-column samples from major stations that were occupied during the U.S. GEOTRACES EPZT cruise (R/V Thomas G. Thompson TN303) from October to December 2013Dissolved Mn was determined at sea by flow injection analysis with in-line pre-concentration on resin-immobilized 8-hydroxyquinoline and colorimetric detection.
Size-fractionated major and minor particle composition and concentration collected from RV Thompson (TN303) along the US GEOTRACES EPZT transect in the Eastern Tropical Pacific during 2013 (US GEOTRACES EPZT project)Ran samples Lachat QuikChem 8000 Flow Injection Analyzer
Shipboard flow injection analyis (FIA) of dissolved Al and Fe from R/V Knorr cruise KN199-04 (GA03) in the Subtropical northern Atlantic Ocean in 2010 (U.S. GEOTRACES NAT project)Dissolved Fe was determined using a Flow Injection Analysis scheme with spectrophometric detection (Rainin Dynamax UV-C). Major components of the scheme include a Rabbit peristaltic pump, a Dynamax FL-1 fluorometer, a Rainin A/D board, and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. Flow Injection Analyzer
Shipboard flow injection analyis (FIA) of dissolved Al, Fe, and Mn from R/V Knorr cruise KN204-01 (GA03) in the Subtropical northern Atlantic Ocean in 2011 (U.S. GEOTRACES NAT project)Dissolved Fe and Mn were determined using a Flow Injection Analysis scheme with spectrophometric detection (Rainin Dynamax UV-C). Major components of the scheme include a Rabbit peristaltic pump, a Dynamax FL-1 fluorometer, a Rainin A/D board, and a Macintosh G3 computer running Rainin MacIntegrator v 1.4.3 to log and reduce data. Flow Injection Analyzer
Dissolved aluminum (Al) and manganese (Mn) and total dissolvable Al and Mn from surface water samples collected during three cruises in 2010 in the northern Gulf of AlaskaFlow Injection Analysis
Dissolved aluminum (Al) and manganese (Mn) and total dissolvable Al and Mn from subsurface water samples collected during three cruises in 2010 in the northern Gulf of AlaskaFlow Injection Analysis
Phosphate Profile Data Comparison between Programmable Flow Injection (pFI) and AA3 Autoanalyzer Methods from R/V Kilo Moana KM2210 in the North Pacific Subtropical Gyre during September 2022 (pFI-SI-LOV project)One set of samples was analyzed using a pFI analyzer (miniSIA2, GlobalFIA, USA). This instrument was furnished with two High Flow milliGAT pumps with stainless steel heads, a plexiglass 8-port Lab-On-Valve, a 20 cm Long Path Linear Flow cell equipped with a Tungsten-Halogen lamp and a VIS-NIR Flame spectrophotometer (Ocean Insight, USA). pFI analyzer (miniSIA2, GlobalFIA, USA)
Phosphate Profile Data Comparison between Programmable Flow Injection (pFI) and AA3 Autoanalyzer Methods from R/V Kilo Moana KM2210 in the North Pacific Subtropical Gyre during September 2022 (pFI-SI-LOV project)Samples not analyzed with the mini SIA2 pFI analyzer were analyzed using a SIO's AA3 analyzer (Seal Analytical, USA) following the vendor's established GO-SHIP protocols.  SIO's AA3 analyzer (Seal Analytical, USA)
Fluorescent characteristics of the dissolved organic exudates of two species of crustose coralline algae in two water treatments and their effect on the microbial community cell countSeal Analytical Segmented Flow Injection AutoAnalyzer AA3HR
HMW and LMW DOC recovery parameters from waters collected from the North Pacific Subtropical Gyre and Central North AtlanticLachat QuickChem 8000 Flow Injection Analyzer
Hydrogen peroxide influence on toxicity of cyanobacterial harmful algal blooms (CHABs) in Lake Erie and other eutrophic waters from 2017 - 2019FeLume, Waterville Analytical, purchased 2011 The description from the company website of Waterville Analytical, http://watervilleanalytical.com/products.html The FeLume(II) is a general purpose, FIA-based, analytical system for the analysis of Fe(II), Fe(III), Cu(II), Co(II), hydrogen peroxide, and superoxide.  FeLume
Nutrient and nitrate isotope data from the southern Benguela upwelling system from February to August 2017Nitrate+nitrite concentrations were measured using a Lachat QuickChem flow injection analysis platform in a configuration with a detection limit of 0.1 µM.  Lachat QuickChem flow injection analysis platform
Incubation experiment data from R/V Melville, R/V Roger Revelle cruises MV1101, RR1202 in the Southern Ocean (30-60S); 2011-2012 (Great Calcite Belt project)Dissolved nutrients were analyzed by ODF technician on ship using segmented flow injection analysis following the approach of Parsons et al (1984). Flow Injection Analyzer
Biological, physical, and chemical data from surface Transect 5 on MV1405 (IRN-BRU)Nitrate-nitrite, Phosphate, Silicate: Lachat QuickChem 8000 Flow Injection Analysis System Lachat QuickChem 8000 Flow Injection Analysis System
Silicon uptake rates from samples collected during the R/V Point Sur cruise PS1312 along the Central California coast from June to July of 2013 (Diatom Group Si Prod project)University of California Santa Barbara Marine Science Institute’s Analytical Laboratory using flow injection techniques on a QuickChem 8000 analyzer (Lachat Instruments Division, Zellweger Analytics) as described in Brzezinski and Washburn (2011). Brzezinski, M. A., and L. Washburn.  2011.  Phytoplankton primary productivity in the Santa Barbara Channel: Effects of wind-driven upwelling and mesoscale eddies.  Journal of Geophysical Research Oceans, 116, C12013, doi:10.1029/2011JC007397. QuickChem 8000 analyzer
Concentrations of nutrients in total suspended particle (TSP) samples collected near Lake Tahoe from 2006 to 2009QuikChem 8000 Flow Injection Analyzer
Elemental composition of phytoplankton communities from multivariate mesocosm experiments conducted with a natural phytoplankton community from Narragansett Bay, RI.Lachat Quikchem 8500 analyzer (Hach) Lachat Quikchem 8500 analyzer
Phosphate Time Series Data Obtained from an Autonomous Programmable Flow Injection (pFI) Analyzer at CeNVOOS Moss Landing Shore Station during February 2022 (pFI-SI-LOV project)Samples were analyzed autonomously at the station using a pFI analyzer (miniSIA2, GlobalFIA, USA). This instrument was furnished with two High Flow milliGAT pumps with stainless steel heads, a plexiglass 8-port Lab-On-Valve, a 20 cm Long Path Linear Flow cell equipped with a Tungsten-Halogen lamp and a VIS-NIR Flame spectrophotometer (Ocean Insight, USA). The instrument was controlled and the data processed using FloZF software (v 5.2).  miniSIA-2 (GlobalFIA, USA)
Molybdate reactive phosphorus concentrations in NMR pretreatment extracts from sediment samples collected during R/V JOIDES Resolution cruise JRES-336 (IODP336, North Pond) to the western flank of the mid-Atlantic Ridge in November of 2011QuikChem 8000 automated ion analyzer
Molybdate reactive phosphorus concentrations in NMR pretreatment extracts from sediment samples collected during cruises in the Arctic Ocean, California Margin, and Equatorial Pacific from 1992-1998QuikChem 8000 automated ion analyzer
Q incubation data from the R/V Melville (MV1405) cruise along the California coast during July 2014Dissolved nitrate + nitrite (NO3- + NO2-), phosphate (PO43-), and silicic acid (H4SiO4) concentrations were measured shipboard. Lachat Quick Chem 8000 Flow Injection Analysis system
Weekly surface water quality measurements in Narragansett Bay from 1959-2019From 2003 to 2019, surface nutrient samples for PO4, SiO4, NH4, and NO3/2 were filtered with acid washed 60 ml syringes and filtering tips (Millipore) using 0.45 mm cellulose filtering membranes (Millipore). Samples were run on a Lachat Quick Chem 8000 Flow Injection Analyzer. Lachat Quick Chem 8000 Flow Injection Analyzer
Dissolved macronutrient concentrations from incubation experiments performed on RVIB Nathaniel B. Palmer cruise NBP 16-08 from September to October 2016Lachat QuickChem 8500 series 2, 4 channel analyzer Lachat QuickChem 8500
Dissolved macronutrient concentrations from depth profiles from RVIB Nathaniel B. Palmer cruise NBP1608 in the Southern Ocean from September to October 2016Lachat QuickChem 8500 series 2, 4 channel analyzer Lachat QuickChem 8500
Underway dissolved macronutrient concentrations collected on RVIB Nathaniel B. Palmer cruise NBP 16-08 from September to October 2016Lachat QuickChem 8500 series 2, 4 channel analyzer Lachat QuickChem 8500
Solution 31P NMR spectra files from sediment samples collected during R/V JOIDES Resolution cruise JRES-336 (IODP336, North Pond) to the western flank of the mid-Atlantic Ridge in November of 2011QuikChem 8000 automated ion analyzer
Solution 31P NMR spectra files from sediment samples collected during cruises in the Arctic Ocean, California Margin, and Equatorial Pacific from 1992-1998QuikChem 8000 automated ion analyzer
Data on how nutrient and sediment loading affect coral functionality in a tropical branching coralQuikChem 8500 Series 2, Lachat Instruments, Zellweger Analytics
Nutrient monitoring data collected as part of macroalgal surveys in Sitka Sound, Alaska kelp beds from 2016 to 2020Lachat QuikChem 8000 Flow Injection Analyzer at the University of California Santa Cruz Marine Analytical Laboratory (detection limit < 0.28 µM NOx, average run measurement error < 0.1 µM NOx). Lachat QuikChem 8000
Concentration of major dissolved nutrients sampled from CTD hydrocasts from R/V Melville cruise MV1008 in the Costa Rica Dome in 2010 (CRD FLUZiE project)Major nutrient concentrations were estimated using Flow Injection Analysis (FIA) at the Analytical Facility, Marine Science Institute, UCSB. Samples were run on a Lachat Instuments QuikChem 8000 FIA. Lachat Instuments QuikChem 8000 FIA
Dissolved nutrients from phyto and microzooplankton experiments from the RVIB Nathaniel B. Palmer NBP0601 cruise in the Ross Sea, Southern Ocean from 2005-2006 (CORSACS project, Antarctic microzooplankton project)Samples for dissolved nutrients were analyzed using a Lachat QuikChem 8000 Flow Injection Analysis System. FIA
Dissolved nutrients from phytoplankton and microzooplankton experiments on the RVIB Nathaniel B. Palmer NBP0608 cruise in the Ross Sea, Southern Ocean during 2006(CORSACS project, Antarctic microzooplankton project)Samples for dissolved nutrients were analyzed using a Lachat QuikChem 8000 Flow Injection Analysis System. Flow Injection Analyzer
Results of a study examining how foundation species loss alters multiple ecosystem functions based on community surveys and biogeochemical sampling of tidepools in the Otter Rock Marine Reserve (ORMR) and Marine Garden, Oregon USA from June to August 2019Lachat Quickchem 8000 Flow Injection Analyzer (Hach)
Other solutes from vertical profiles from multi- and gravity cores from two cruises, R/V Robert Gordon Sproul SP1215 and R/V New Horizon NH1319, in the Santa Barbara and Santa Monica Basins in 2012 and 2013
Environmental data collected in marine lakes in Palau in 2010 from small boatsSamples were analyzed for ammonium, nitrite, nitrite+nitrate, and phosphate on a Lachat QuikChem 8000 Flow Injection Analyzer (Hach Company, Loveland, CO, USA). Lachat QuikChem 8000 Flow Injection Analyzer
Sediment pore water and solid phase geochemical analyses from samples collected on R/V Savannah cruise SAV-15-18 at the Cape Lookout Continental Shelf and Slope during July 2015DIC was measured by flow injection analysis with peristaltic pump (Gilson), conductivity detector (Fisher Scientific), and integrator with LC-100 software (Analytical Systems, Inc.).
Sediment pore water and solid phase geochemical analyses from samples collected on R/V Savannah cruise SAV-16-16 at the Cape Lookout Continental Shelf and Slope during May 2016Flow Injection Analysis with peristaltic pump (Gilson), conductivity detector (Fisher Scientific), and integrator with LC-100 software (Analytical Systems, Inc.) Flow Injection Analysis
Sediment pore water and solid phase geochemical analyses from samples collected on R/V Savannah cruise SAV-17-15 in the Gulf of Mexico during July and August 2017Flow Injection Analysis with peristaltic pump (Gilson), conductivity detector (Fisher Scientific), and integrator with LC-100 software (Analytical Systems, Inc.) Flow Injection Analysis
Pseudo-nitzschia spp. cell counts, nutrients water temperature and salinity, and concentrations of the toxin domoic acid from weekly samples and offshore cruises with the Northeast U.S. Shelf (NES) Long-Term Ecological Research (LTER)Lachat QuickChem 8500 (Hach, Loveland, CO, USA) at the URI Marine Science Research Facility (Narragansett, RI, USA)
Results from a study of physiological responses of Ulva lactuca to ocean acidification and nutrient enrichmentNO3- concentrations in the culture tanks were determined from samples sent to the University of California, Santa Barbara Marine Science Institute Analytical Lab and were analyzed using a Lachat Instruments flow injection analysis instrument (QuikChem 8000) Lachat Instruments flow injection analysis instrument (QuikChem 8000)
Nutrients (phosphate and nitrite+nitrate) from daily sampling at the Santa Monica Pier (SMP), Santa Monica Bay, CA from 2018 to 2019Quickchem 8500
Hydrological, biogeochemcial and N2-fixer qPCR-derived abundance data for May 2017 (SP1714) and October (SP1724) SCCS cruises. Nutrients were measured on a Lachat QuikChem 8000 Flow Injection Analyzer. Lachat QuikChem 8000 Flow Injection Analyzer
Sediment NO3 reduction rates, associated genes, and environmental data from bimonthly samples collected along the York River Estuary from June 2018 to April 2019Nutrient analyses (NO₃, NO₂, NH₄) were performed with a Lachat QuikChem 8000 automated ion analyzer (Lachat Instruments, Milwaukee, WI, USA). Lachat QuikChem 8000
Total molybdate reactive and unreactive phosphorus concentrations from sediment extracts from sediment samples collected during cruises in the Arctic Ocean, California Margin, and Equatorial Pacific from 1992-1998QuikChem 8000 automated ion analyzer
Aggregate Sinking Velocity from the CO2 Aggregation Experiment from UCSB Marine Science Institute Passow Lab from 2009 to 2010 (OA - Ocean Acidification and Aggregation project)Concentrations of NO3+NO2, PO4 and Si(OH)4 in the initial phytoplankton-detritus mixture were measured by simultaneous flow injection analysis (QuickCem 8000, Lachat Instruments) in the Analytical Laboratory of the Marine Science Institute at UCSB from pre-filtered frozen samples. Flow Injection Analyzer - QuickCem 8000, Lachat Instruments
Aggregate Size from the CO2 Aggregation Experiment from UCSB Marine Science Institute Passow Lab from 2009 to 2010 (OA - Ocean Acidification and Aggregation project)Concentrations of NO3+NO2, PO4 and Si(OH)4 in the initial phytoplankton-detritus mixture were measured by simultaneous flow injection analysis (QuickCem 8000, Lachat Instruments) in the Analytical Laboratory of the Marine Science Institute at UCSB from pre-filtered frozen samples. Flow Injection Analyzer - QuickCem 8000, Lachat Instruments
BioChemical results from the CO2 Aggregation Experiment from UCSB Marine Science Institute Passow Lab from 2009 to 2010 (OA - Ocean Acidification and Aggregation project)Concentrations of NO3+NO2, PO4 and Si(OH)4 in the initial phytoplankton-detritus mixture were measured by simultaneous flow injection analysis (QuickCem 8000, Lachat Instruments) in the Analytical Laboratory of the Marine Science Institute at UCSB from pre-filtered frozen samples. Flow Injection Analyzer - QuickCem 8000, Lachat Instruments
Carbonate System results from the CO2 Aggregation Experiment from UCSB Marine Science Institute Passow Lab from 2009 to 2010 (OA - Ocean Acidification and Aggregation project)Concentrations of NO3+NO2, PO4 and Si(OH)4 in the initial phytoplankton-detritus mixture were measured by simultaneous flow injection analysis (QuickCem 8000, Lachat Instruments) in the Analytical Laboratory of the Marine Science Institute at UCSB from pre-filtered frozen samples. Flow Injection Analyzer - QuickCem 8000, Lachat Instruments
General Information about the CO2 Aggregation Experiment from UCSB Marine Science Institute Passow Lab from 2009 to 2010 (OA - Ocean Acidification and Aggregation project)Concentrations of NO3+NO2, PO4 and Si(OH)4 in the initial phytoplankton-detritus mixture were measured by simultaneous flow injection analysis (QuickCem 8000, Lachat Instruments) in the Analytical Laboratory of the Marine Science Institute at UCSB from pre-filtered frozen samples. Flow Injection Analyzer - QuickCem 8000, Lachat Instruments
pH data from the CO2 Aggregation Experiment from UCSB Marine Science Institute Passow Lab from 2009 to 2010 (OA - Ocean Acidification and Aggregation project)Concentrations of NO3+NO2, PO4 and Si(OH)4 in the initial phytoplankton-detritus mixture were measured by simultaneous flow injection analysis (QuickCem 8000, Lachat Instruments) in the Analytical Laboratory of the Marine Science Institute at UCSB from pre-filtered frozen samples. Flow Injection Analyzer - QuickCem 8000, Lachat Instruments
Programmable Flow Injection (pFI) Silicate Vertical Profile Data from R/V Investigator IN2023_V04 in the Southern Ocean during June 2023 (pFI-SI-LOV project)We used a miniSIA-2 instrument (miniSIA2, GlobalFIA, Fox Island, USA) equipped with a 8-port LOV unit and a 20 cm flow cell furnished with a Tungsten Halogen light source and UV-VIS spectrophotometer (Ocean Insight, USA) and a 14 position auto sampler (GlobalFIA, USA). miniSIA-2 (GlobalFIA, Fox Island, USA)
Total phosphorus and metal concentrations from sediment extracts from samples collected during cruises in the Arctic Ocean, California Margin, and Equatorial Pacific from 1992-1998QuikChem 8000 automated ion analyzer
Total phosphorus concentrations in NMR sediment pretreatment extracts from samples collected during cruises in the Arctic Ocean, California Margin, and Equatorial Pacific from 1992-1998QuikChem 8000 automated ion analyzer
Trace Metals from ARSV Laurence M. Gould LMG0402 in the Antarctica, Drake Passage, Scotia Sea, Bransfield Strait from February to March 2004 (BWZ project)Flow Injection Analyzer
Trace Metals from RVIB Nathaniel B. Palmer NBP0606 in the Antarctica, Drake Passage, Scotia Sea, Bransfield Strait from July to August 2006 (BWZ project)Flow Injection Analyzer
Water column data collected during Dataflow cruises in the lower York River Estuary, VA during and following two successive harmful algal bloomsWater column analyses (NO3, NO2, NH4, PO4) were performed with a Lachat QuikChem 8000 automated ion analyzer (Lachat Instruments, Milwaukee, WI, USA). Lachat QuikChem 8000
[DEPRECATED] Recovery parameters, isotopic composition, and elemental composition of HMW and LMW DOM collected in the North Pacific Subtropical Gyre on R/V Kilo Moana (KM1506, KM1515) during 2015Used to analyze DIN Lachat Quick-Chem 8000 Flow injection analyzer