Current flow, pressure, and oxygen concentrations recorded by the 3OEC-instrument in the Florida Keys from 11-17 July 2017 | The Pyrosience oxygen sensors were pre- and post calibrated using air saturated seawater (100% air saturation) and seawater with addition of sodium sulfite (0% air saturation).
Oxygen sensor (Pyroscience) Accuracy:
at 5% a.s./0.44 mg/L ±0.1% a.s. ±0.01 mg/L
at 95% a.s./8.8 mg/L ±1% a.s. ±0.1 mg/L
Resolution:
at 5% a.s./0.44 mg/L 0.05% a.s. 0.005 mg/L
at 95% a.s./8.8 mg/L 0.25% a.s. 0.025 mg/L
Detection Limit: 0.1% a.s. 0.01 mg/L
| Pyrosience oxygen sensors |
Abalone respiration rates from a fully factorial mesocosm experiment manipulating pH and diet from June to October 2017 (High latitude kelp dynamics project) | Self-adhesive oxygen sensor spot. Oxygen is measured contactless and non-destructively from the outside, through the vessel wall.
| PreSens SP-PSt4-SA |
Abalone respiration rates from a fully factorial mesocosm experiment manipulating pH and diet from June to October 2017 (High latitude kelp dynamics project) | A stand-alone fiber optic oxygen meter.
| Presens Fibox IV |
Physical environmental data from Little Lagoon, Alabama collected from 2012-2013. | Used to determine DO
| YSI 556 Multiparameter Meter |
Organismal physiological metrics from time series experiments on samples collected on R/V Atlantic Explorer cruise AE1910 in May 2019 | Oxygen concentration in each chamber was then measured non-invasively and continuously (every 60 seconds) for approximately 3 hours using two FireSting optical oxygen meters (PyroScience, Aachen Germany).
| FireSting optical oxygen meters |
Oxygen measurements from kelp forests and urchin barrens on the Aleutian Islands, Alaska from R/V Oceanus cruises OC1606A and OC1707A during 2016-2017 | | PME Minidot Oxygen loggers |
PAR measurements from kelp forests and urchin barrens on the Aleutian Islands, Alaska from R/V Oceanus cruises OC1606A and OC1707A during 2016-2017 | | PME Minidot Oxygen loggers |
ARISA relative abundances (bacterial community structure), San Pedro Channel, 5 depths, 2014 (Bacterial, Archaeal, and Protistan Biodiversity project, Marine Viral Dynamics project) | Sea-bird, model 13
| Dissolved Oxygen Sensor |
Hatching count and survival statistics of Atlantic silverside (Menida menidia) larvae reared under ambient or hypoxia/acidification treatments during cross-generational laboratory experiments in 2022 | DO levels in individual rearing units were cross-verified using a handheld Pyroscience Firesting®-GO2 meter fitted with an optical DO sensor. A two-point calibration (100% and 0% DO) was made daily using air-saturated seawater and a concentrated NaSO3 seawater solution.
| Pyroscience Firesting®-GO2 |
Hatching count and survival statistics of Atlantic silverside (Menida menidia) larvae reared under ambient or hypoxia/acidification treatments during cross-generational laboratory experiments in 2022 | The mixing tank received a continuous flow of ambient seawater, with DO, pH, and temperature measurements taken every 10 seconds by Pyroscience® Ultra Compact (PICO) DO and pH meters, fitted with fiberoptic DO or pH sensors and PT100 temperature sensors.
Calibration of the probes was performed weekly according to the manufacturer's guidelines using oxygen and pHT calibration solutions provided by Pyroscience®.
DO levels in individual rearing units were cross-verified using a handheld Pyroscience Firesting®-GO2 meter fitted with an optical DO sensor. A two-point calibration (100% and 0% DO) was made daily using air-saturated seawater and a concentrated NaSO3 seawater solution.
| Pyroscience® Ultra Compact (PICO) DO meter |
Morphological measurements of Atlantic silverside (Menidia menidia) larvae reared under ambient or hypoxia/acidification treatments during cross-generational laboratory experiments in 2022 | The mixing tank received a continuous flow of ambient seawater, with DO, pH, and temperature measurements taken every 10 seconds by Pyroscience® Ultra Compact (PICO) DO and pH meters, fitted with fiberoptic DO or pH sensors and PT100 temperature sensors.
Calibration of the probes was performed weekly according to the manufacturer's guidelines using oxygen and pHT calibration solutions provided by Pyroscience®.
DO levels in individual rearing units were cross-verified using a handheld Pyroscience Firesting®-GO2 meter fitted with an optical DO sensor. A two-point calibration (100% and 0% DO) was made daily using air-saturated seawater and a concentrated NaSO3 seawater solution.
| Pyroscience® Ultra Compact (PICO) DO meter |
Morphological measurements of Atlantic silverside (Menidia menidia) larvae reared under ambient or hypoxia/acidification treatments during cross-generational laboratory experiments in 2022 | DO levels in individual rearing units were cross-verified using a handheld Pyroscience Firesting®-GO2 meter fitted with an optical DO sensor. A two-point calibration (100% and 0% DO) was made daily using air-saturated seawater and a concentrated NaSO3 seawater solution.
| Pyroscience Firesting®-GO2 |
Barnacle respiration data from University of Washington Friday Harbor Laboratories, Friday Harbor WA, Cantilever Point; 2010-2013 (Intertidal Temp Effects project) | Oxygen concentrations were measured using a fiber-optic oxygen sensor equipped with a needle-like probe tip of 1.5 mm diameter (FOXY-R, Ocean Optics, Dunedin, FL, USA).
| Dissolved Oxygen Sensor |
Benthic Ecosystem and Acidification Measuring System (BEAMS) data from two Bermuda sites collected during 2015 (BEAMS project) | | |
Benthic Ecosystem and Acidification Measuring System (BEAMS) data from two sites on the western terrace of the Palmyra Atoll collected during 2014 (BEAMS project) | Used by the Benthic Ecosystem and Acidification Measuring System (BEAMS)
| autonomous oxygen sensor |
| | PreSens Microx T3 micro-fiber optic oxygen sensor |
Oxygen concentrations measured at increasing distances over coral-algal interactions at Moorea, French Polynesia (Vermetids_Corals project) | Oxygen concentration profiles were measured using a PreSens needle microsensor oxygen probe (diameter: | PreSens needle microsensor oxygen probe |
Oxygen concentrations measured at increasing distances over coral-algal interactions at Moorea, French Polynesia (Vermetids_Corals project) | Oxygen concentration profiles were measured using a PreSens needle microsensor oxygen probe (diameter: | PreSens needle microsensor oxygen probe |
Carbonate chemistry data from static and fluctuating pCO2 x dissolved oxygen (DO) experiments on Menidia menidia | Dissolved oxygen (DO) – Optical DO probe (Hach LDO Model 2)
| Hach LDO Model 2 |
CO2 × temperature specific early life survival and growth of Menidia menidia assessed by 5 factorial experiments | | dissolved oxygen probe |
| Dissolved oxygen: TROLL 9500
| TROLL 9500 |
| Unisense optode (oxygen-sensitive minisensor) connected to the OXY-4 software (Chanel fibreoptic oxygen meter, Presens, Regensburg, Germany).
| Unisense optode |
Copepod species abundances from MOCNESS tows from R/V Thomas G. Thompson and R/V Malcolm Baldridge cruises in the Arabian Sea from 1994-1995 (Arabian Sea project, Arabian Sea Diapausing Copepods project) | Sea-Bird SBE 13
| oxygen probe |
Physiology measurements on collected coral pairs from Kaneohe Bay, Oahu, HI between July and December 2019 | PreSens, OXY-10 ST: Software and oxygen optode device for measuring metabolic rates
| PSt7 oxygen optode (PreSens) |
Montipora capitata and Porites compressa Physiological Measurements for Experimental Corals and Parent Colonies from 2014-2015 (RAPID Hawaii project) | YSI ProODO Optical Dissolved Oxygen probes were used to measure dissolved oxygen during coral incubations for use in the calculation of photosynthesis and respiration rates.
| YSI ProODO Optical DIssolved Oxygen |
Oxygen evolution data for macroalgae during photo physiology incubations for photosynthesis-irradiance curves from August to September 2017 (High latitude kelp dynamics) | In vivo photophysiology was characterized for all red algal species at the end of the experiment by measuring the rate of oxygen evolution produced by algal thalli at seven irradiance levels. Following the final buoyant mass measurement, a small piece of thallus (mean ± SE: B. orbigniana: 0.17 ±0.02g; Crusticorallina spp.: 0.53 ± 0.03g; C. ruprechtiana: 0.07 ± 0.003g) was taken from haphazardly selected individuals (n=3 treatment-1 species-1) and placed in a 69mL incubation chamber filled with seawater from the associated aquaria and equipped with a stir bar and an oxygen sensor spot (PreSens SP-PSt4-SA). Sensor spots were calibrated daily using a two-point correction of 100% (air-saturated water) and 0% (1% Na2SO3 and 0.05% Co(NO3)2 standard solution) saturation.
| PreSens SP-PSt4-SA oxygen sensor spots |
Oxygen evolution data for macroalgae during photo physiology incubations for photosynthesis-irradiance curves from August to September 2017 (High latitude kelp dynamics) | A fiber optic O2 sensor (Fibox IV, Presens) was used to record the dissolved oxygen concentration in each chamber at 30, 45 and 60min after each irradiance level was reached.
| Presens Fibox IV fiber optic O2 sensor |
Results of laboratory study examining effects of elevated concentrations of seawater carbon dioxide and altered salinity on rates of oxygen utilization by larval porcelain crabs (Petrolisthes cinctipes) | Respirometry trials were conducted in seawater at ambient pCO2 using a dissolved oxygen meter (model 781b Strathkelvin
Instruments Ltd., Glasgow, UK) with a Clark-type microcathode polarographic electrode with a 22 micron diameter platinum
cathode and silver/silver chloride anode connected by a buffered potassium chloride electrolyte solution (model 1302).
| 781b Strathkelvin Instruments Ltd. |
Results of laboratory study examining effects of elevated concentrations of seawater carbon dioxide and altered salinity on rates of oxygen utilization by larval porcelain crabs (Petrolisthes cinctipes) | Respirometry trials were conducted in seawater at ambient pCO2 using a dissolved oxygen meter (model 781b Strathkelvin
Instruments Ltd., Glasgow, UK) with a Clark-type microcathode polarographic electrode with a 22 micron diameter platinum
cathode and silver/silver chloride anode connected by a buffered potassium chloride electrolyte solution (model 1302).
| 781b Strathkelvin Instruments Ltd. |
Results of laboratory study examining effects of elevated concentrations of seawater carbon dioxide and altered salinity on rates of oxygen utilization by larval porcelain crabs (Petrolisthes cinctipes) | Respirometry trials were conducted in seawater at ambient pCO2 using a dissolved oxygen meter (model 781b Strathkelvin
Instruments Ltd., Glasgow, UK) with a Clark-type microcathode polarographic electrode with a 22 micron diameter platinum
cathode and silver/silver chloride anode connected by a buffered potassium chloride electrolyte solution (model 1302).
| 781b Strathkelvin Instruments Ltd. |
Results of laboratory study examining effects of elevated concentrations of seawater carbon dioxide and altered salinity on rates of oxygen utilization by larval porcelain crabs (Petrolisthes cinctipes) | Respirometry trials were conducted in seawater at ambient pCO2 using a dissolved oxygen meter (model 781b Strathkelvin
Instruments Ltd., Glasgow, UK) with a Clark-type microcathode polarographic electrode with a 22 micron diameter platinum
cathode and silver/silver chloride anode connected by a buffered potassium chloride electrolyte solution (model 1302).
| 781b Strathkelvin Instruments Ltd. |
Deployment history of sensors recording dissolved oxygen from Massachusetts from 2012. | Recorded dissolved oxygen concentrations and temperature.
| EXO2, YSI TIDE1, YSI PIE1, YSI PIE2, HOBODO1, and HOBODO2 |
Dissolved oxygen and potential density measurements from the R/V Atlantis, R/V Ronald Brown, & E/V Nautilus in the Gulf of Mexico & Florida from 2010-2014 (Lophelia OA project) | All dissolved oxygen measurements collected using this instrument
| SBE 43 dissolved oxygen sensor |
Dissolved O2 and percent O2 saturation, measured optically in situ, and barometric pressure, measured by YSI handheld meter, from the PICO time-series station (34.7181 deg N, 76.6707 deg W) from 2010-2012 (PICO project) | A YSI ProODO (Optical Dissolved Oxygen) handheld meter was used. The YSI ProODO meter measures dissolved oxygen (% and mg/L), temperature, and barometric pressure. See more information from the manufacturer.
| Dissolved Oxygen Sensor |
Dissolved oxygen measurements collected at the height of El Niño at Jarvis Island in 2015 and 2016 | (RBR, 1 min sampling interval)
| |
Dissolved oxygen of pore water from sediment gravity cores, and push cores taken during R/V Atlantis cruise AT26-24 at the Dorado Outcrop near Cocos Ridge in December of 2014 (Dorado Outcrop project) | | ALVIN needle-type oxygen optode |
DO and temperature from a soloDO logger measured with Alvin during the R/V Atlantis cruise AT26-24 at the Dorado Outcrop near Cocos Ridge from November to December 2014 | Prototype of the soloDO logger (RBR Ltd., Canada).
| prototype soloDO |
Environmental, sensory data (temperature, light intensity, salinity, pH, dissolved oxygen, depth) sampled in August 2019 in Carrie Bow Caye, Belize | YSI ProDSS Handheld Optical Dissolved Oxygen Sensor (626900) 0 to 20 mg/L: ±0.1 mg/L or 1% of reading, whichever is greater
| YSI ProDSS Handheld Optical Dissolved Oxygen Sensor |
Experimental oxygen consumption for two iron oxidizing bacteria at 5˚C from March to November 2018 | A PreSens OXY-4 SMA 4-channel optode was used for oxygen concentration measurements.
| PreSens OXY-4 SMA 4-channel optode |
Experimental oxygen consumption data for two iron oxidizing bacteria with pyrrhotite as iron source from April to December 2018 | A PreSens OXY-4 SMA 4-channel optode was used for oxygen concentration measurements.
| PreSens OXY-4 SMA 4-channel optode |
Physiological metrics recorded at the end of experiments conducted to examine two coral species' responses to thermal stress | | fiberoptic oxygen probes (FireSting O2, Pyroscience) |
Spectral analyses of high-frequency data during two hour-long periods from the ECHOES system deployed at three sites in the Florida Keys in June 2018 | | FirestingO2 Mini fiber-optic O2 meter |
Current velocity, wave velocity, and O2, H+, and momentum flux from the ECHOES system deployed at three sites in the Florida Keys in June 2018 | | FirestingO2 Mini fiber-optic O2 meter |
Vertical profile data collected by CTD in a subtropical, pelagic environment from R/V F.G. Walton Smith cruise WS15161 in the Straits of Florida in June 2015 (OSTRICH project) | The conductivity-temperature-depth (CTD) instrument package is a high resolution vertical profiling sampling system. It is instrumented with a set of environmental sensors including: Seabird CTD, Seabird dissolved O2, and Wet Labs Fluorometer (ECO).
| Seabird dissolved O2 |
Maximum potential quantum efficiency of Photosystem II (Fv/Fm) for two coral species, Acropora hemprichii and Porites lobata, in response to thermal stress | | fiberoptic oxygen probes (FireSting O2, Pyroscience) |
Growth data from static and fluctuating pCO2 x dissolved oxygen (DO) experiments on Menidia menidia | Dissolved oxygen (DO) – Optical DO probe (Hach LDO Model 2)
| Hach LDO Model 2 |
GTC CTD profiles along with US GEOTRACES North Atlantic Transect from the R/V Knorr KN199-04 cruise in the subtropical N. Atlantic during 2010 (U.S. GEOTRACES NAT project) | Dissolved Oxygen Sensor
| Dissolved Oxygen Sensor |
ODF CTD profiles along with US GEOTRACES North Atlantic Transect from the R/V Knorr KN199-04 cruise in the subtropical N Atlantic during 2010 (U.S. GEOTRACES NAT project) | Dissolved Oxygen Sensor
| Dissolved Oxygen Sensor |
GTC one meter-averaged downcast CTD profiles along the US GEOTRACES North Atlantic Transect from the R/V Knorr KN204-01 cruise in the subtropical N. Atlantic during 2011 (U.S. GEOTRACES NAT project) | Dissolved Oxygen Sensor
| Dissolved Oxygen Sensor |
ODF one meter-averaged downcast CTD profiles along the US GEOTRACES North Atlantic Transect from the R/V Knorr KN199-04 cruise in the subtropical N. Atlantic from 2010 (U.S. GEOTRACES NAT project) | Dissolved Oxygen Sensor - A second dissolved oxygen plus oxygen
temperature sensor (JFE Advantech RINKO-III)
SIOR/30L-Niskin Rosette/CTD casts were performed with a package consisting of a 12-bottle rosette
frame (SIO/STS), a 24-place carousel (SBE32) and 12 30L General Oceanics bottles with an absolute
volume of 30L each. Underwater electronic components consisted of a Sea-Bird Electronics SBE9plus
CTD with dual pumps (SBE5), dual temperature (SBE3plus), reference temperature (SBE35RT) dual
conductivity (SBE4C), dissolved oxygen (SBE43), transmissometer (WET Labs C-Star), fluorometer
(Seapoint SCF) and altimeter (Tritech LPRA-200 or Simrad 807). A second dissolved oxygen plus oxygen
temperature sensor (JFE Advantech RINKO-III) was incorporated into the data stream for future sensor
evaluation; it was not processed for this cruise.
| Dissolved Oxygen Sensor |
Data pertaining to the development of larvae past the planula stage from experiments investigating heat priming in Nematostella vectensis | | oxygen sensor spots (Loligo Systems, Viborg, Denmark) |
Data pertaining to dose-response curves (DRC) quantifying survival of larvae after exposure to heat ramps from experiments investigating heat priming in Nematostella vectensis | | oxygen sensor spots (Loligo Systems, Viborg, Denmark) |
Expression of heat shock protein 70 (HSP70) in larvae at 11 days post-fertilization (DPF) from experiments investigating heat priming in Nematostella vectensis | | oxygen sensor spots (Loligo Systems, Viborg, Denmark) |
Heat tolerance (survival) of juveniles at 6 WPF following heat shock from experiments investigating heat priming in Nematostella vectensis | | oxygen sensor spots (Loligo Systems, Viborg, Denmark) |
Lethal temperature 50s (LT50s) displayed by larvae derived from dose-response curves after heat shock from experiments investigating heat priming in Nematostella vectensis | | oxygen sensor spots (Loligo Systems, Viborg, Denmark) |
Long-term body column lengths and tentacle numbers of larvae and juveniles from experiments investigating heat priming in Nematostella vectensis | | oxygen sensor spots (Loligo Systems, Viborg, Denmark) |
Respiration rates and protein content of larvae from experiments investigating heat priming in Nematostella vectensis | | oxygen sensor spots (Loligo Systems, Viborg, Denmark) |
Sizes of larvae from 4-11 days post-fertilization from experiments investigating heat priming in Nematostella vectensis | | oxygen sensor spots (Loligo Systems, Viborg, Denmark) |
Station CTD profiles from R/V Hugh R. Sharp HRS1610 in the Mid-Atlantic coastal waters from August 2016 (CyanateInTheSea project) | Oxygen measurements were made using a Seabird SBE 911 conductivity-temperature-depth (CTD) unit combined with a fluorometer and oxygen sensor mounted to a rosette sampler.
| Oxygen sensor |
Data from moored instruments (pH, dissolved oxygen, temperature, salinity, PAR, pressure) at 9 depths outside and inside the kelp canopy at Hopkins Marine Station, recorded between June and October 2018. | 3 MiniDO2T dissolved oxygen loggers (Precision Measurement Engineering (PME), 5 minute
sampling frequency)
| MiniDO2T dissolved oxygen logger |
CTD profiles from the Lake Superior collected during various R/V Blue Heron cruises between 2000-2002 (IRONMAN project) | | |
Seawater conditions monitored and recorded during two separate laboratory experiments in 2017 to acclimate krill to dissolved oxygen (DO) or pH conditions. | Vernier optical dissolved oxygen probes
| Vernier optical dissolved oxygen probes |
Physiological observations of Euphausia pacifica after a ten-day acclimation to dissolved oxygen (DO) and pH conditions in two separate laboratory experiments. | PreSens Microx 4 with PSt7 optical oxygen sensors.
| PreSens Microx 4 with PSt7 |
Physiological observations of Euphausia pacifica sampled in Puget Sound, WA aboard R/V Clifford A. Barnes during cruises CB1073 and CB1078 in 2017. | PreSens Microx 4 with PSt7 optical oxygen sensors
| PreSens Microx 4 with PSt7 |
Calcification rates from pH experiments on Lophelia pertusa specimens collected from the Norwegian Skagerrak and the Gulf of Mexico (Lophelia OA project) | Measured dissolved oxygen concentrations
| Strathkelvin 782 dual oxygen meter |
Feeding records for pH experiments conducted on Lophelia pertusa specimens collected in the Norwegian Skagerrak and the Gulf of Mexico (Lophelia OA project) | Measured dissolved oxygen concentrations
| Strathkelvin 782 dual oxygen meter |
Respiration rates for pH experiments on L. pertusa specimens collected in the Norwegian Skagerrak and the Gulf of Mexico (Lophelia OA project) | Measured dissolved oxygen concentrations
| Strathkelvin 782 dual oxygen meter |
Data describing individual aerial respiration rates for limpets in trials conducted at the Hopkins Marine Station in 2013 (Experiments in a Model Ecosystem project) | SP-PSt3-NAU-D5-YOP, PreSens Precision Sensing
| ruthenium sensor spots |
Data describing individual aquatic respiration rates for limpets in trials conducted at the Hopkins Marine Station in 2013 (Experiments in a Model Ecosystem project) | SP-PSt3-NAU-D5-YOP, PreSens Precision Sensing
| ruthenium sensor spots |
DOC, oxygen and pH from samples collected near the Line Islands, Central Pacific in 2013 | | |
Copepod Pressure Vessel Experiments from samples collected from the East Pacific Rise during ROV SuBastian deployments and R/V Falkor (too) cruise FKt230627 in June-July 2023 | Oxygen levels were measured with a Fibox 4 fiber optic oxygen meter to monitor whether the samples were oxic or anoxic.
| Fibox 4 stand-alone fiber optic oxygen meter |
Data describing oxygen, temperature, and salinity in Marsh Pond in Massachusetts from 2014. | Measured oxygen saturation, not concentration
| Oxygen saturation sensor |
Microbial respiration from microcosm experiments conducted under three light treatments using water originating from West Bay of the Neuse River Estuary, North Carolina USA in 2021 and 2022 | | preSens oxygen optode sensor spot (SP-PSt3-NAU) |
Normalized oxygen from incubations conducted with methylcyclohexane using samples collected from the Gulf of Mexico during June 2015 on R/V Atlantis cruise AT29-02 | | Pyroscience OXSP5 optical oxygen sensors with FireStingO2 oxygen meter |
Normalized oxygen from incubations conducted with methylcyclopentane using samples collected from the Gulf of Mexico during June 2015 on R/V Atlantis cruise AT29-02 | | Pyroscience OXSP5 optical oxygen sensors with FireStingO2 oxygen meter |
Nutrient and cell count data from incubations conducted with methylcyclohexane or methylcyclopentane on samples collected from the Gulf of Mexico during June 2015 on R/V Atlantis cruise AT29-02 | | Pyroscience OXSP5 optical oxygen sensors with FireStingO2 oxygen meter |
Data on how nutrient and sediment loading affect coral functionality in a tropical branching coral | | fiber optic oxygen sensors |
Environmental and physical data associated with ocean acidification microbe adaptation from 2012-2014 | Used to measure dissolved oxygen
| YSI ProODO |
Pore water geochemistry from sediments collected on cruise OC1703A aboard R/V Oceanus and cruise AT36 aboard R/V Atlantis | | FirestingO2 (FSO2-4, PyroScience, Aachen, Germany) |
Pore water geochemistry from sediments collected on cruise OC1703A aboard R/V Oceanus and cruise AT36 aboard R/V Atlantis | | robust oxygen probe (OCROB10, PyroScience) |
Processed eddy covariance measurements from three lander deployments during R/V Oceanus cruises OC1802B and OC1901A along the Oregon shelf in 2018 and 2019. | Pyroscience fiber-optic oxygen sensors (OXB430) (yielded O2).The fiber-optic sensors were activated through PyroScience FireStingO2-Subport modules enclosed in Delrin housings with 12V to 5V power converter circuits produced and integrated by Rockland Scientific (Victoria, BC, Canada).
| Pyroscience fiber-optic oxygen sensors (OXB430) |
Data collected from an experiment on the carbonate system of oyster extrapallial fluid during May to September 2017 | | PreSens SP-PSt-NAU oxygen sensor dot |
Float park phase data collected at depth in the Sargasso Sea from 2013-2014. | Used to sample dissolved oxygen, Sea-Bird Scientific Navis BGCi floats (numbers F033 and F034)
| O2 optode |
Photosynthesis and respiration data recorded during experiments conducted to examine two coral species' responses to thermal stress | | fiberoptic oxygen probes (FireSting O2, Pyroscience) |
Photosynthesis-Irradiance curve (P-E) raw data for coral Orbicella faveolata from Varadero and Rosario reef sites, Colombia, Oct. 2016 and May 2017 (Varadero Reef project) | Used to measure oxygen evolution.
| Optical oxygen meter FireStingO2 (Pyroscience) |
Dissolved oxygen and temperature data from loggers deployed in Bahia Almirante (Coral microbiome resilience project) | Loggers were deployed using Hobo Onset Shuttle and programmed to record hourly measurements.
| OnSET HOBO Dissolved Oxygen Loggers Model U26-001 |
Physiological responses of the coral host and associated endosymbionts measured during two experiments testing the effects of acute and chronic thermal stress on the scleractinian coral, Stylophora pistillata | Oxygen flux in the chambers was measured at 1-s intervals using oxygen probes (FireSting O2, Pyroscience).
| FireSting O2, Pyroscience oxygen probes |
Float profile data collected during surface ascents in the Sargasso Sea from 2013-2014. | Used to sample dissolved oxygen, Sea-Bird Scientific Navis BGCi floats (numbers F033 and F034)
| O2 optode |
Profile data from WireWalker deployments at Mission Beach, California in 2016 at a 50m depth | | RINKO III |
O2 consumption of pteropods held for 1-14 days in three CO2 treatments with pteropods collected with a Reeve net during R/V Tioga cruises in the Gulf of Maine from 2013 to 2014 | PyroScience, Aachen Germany
| FireStingO2 optical oxygen meter |
Shell quality of pteropods held for 1-14 days in three CO2 treatments with pteropods collected with a Reeve net during R/V Tioga cruises in the Gulf of Maine from 2014 to 2015 | FireStingO2 optical oxygen meter (PyroScience, Aachen Germany)
| FireStingO2 optical oxygen meter |
Photosynthesic parameters (calculated alpha, Pmax, Respiration, Ek and Ec) for each P-E curve for coral Orbicella faveolata from Rosaria and Varadero reef sites and Cartagena Bay, Colombia, 2016 and 2017 | Used to measure oxygen evolution.
| Optical oxygen meter FireStingO2 (Pyroscience) |
Results from a study of physiological responses of Ulva lactuca to ocean acidification and nutrient enrichment | Photosynthetic O2 evolution rates were measured using the Qubit systems O2 electrode in a water-jacketed cuvette connected to a laptop using a LabProTM interface
| Qubit systems O2 electrode |
Data from experiments testing the effects of hypoxia on behavior and physiology of two species of rockfish from from 2015-2016 | | Loligo Systems optical oxygen probes |
CTD data and analyses of bottles from CTD rosette samples collected on R/V Hugh R. Sharp cruise HRS1415 in August 2014 | O2 sensor equipped on R/V Sharp's CTD rosette
| |
N2O, 15N2, 15N tissue tracer in oyster aquariums (Oyster Reef N2O Emission project) | Oxygen was measured using a Thermo Orion rugged dissolved oxygen probe.
| Thermo Orion rugged dissolved oxygen probe |
Factory and field calibration data for float oxygen, beam transmission, backscatter, chlorophyll fluorescence and CDOM sensors from the Sargasso Sea from 2013-2014. | Used to sample dissolved oxygen
| SBE63 optode |
Environmental measurements from ARISA samples, San Pedro Channel, 5 depths , 2014 (Bacterial, Archaeal, and Protistan Biodiversity project, Marine Viral Dynamics project) | Sea-bird, model 13
| Dissolved Oxygen Sensor |
Dissolved oxygen (DO) from in-situ flume experiments to manipulate pCO2 on shallow tropical coral reef communities at UCB Gump Research Station Moorea, French Polynesia in May of 2018 | miniDO2T oxygen sensors (Precision Measurement Engineering, Vista, CA; sensor calibrations provided by the manufacturers).
| miniDO2T oxygen sensors |
Dissolved oxygen (DO) flux from in-situ flume experiments to manipulate pCO2 on shallow tropical coral reef communities at UCB Gump Research Station Moorea, French Polynesia in May of 2018 | miniDO2T oxygen sensors (Precision Measurement Engineering, Vista, CA; sensor calibrations provided by the manufacturers).
| miniDO2T oxygen sensors |
Sulfate reduction energetics at Main Endeavor grotto chimney from samples collected on RV Atlantis (AT18-08) during Jason II dives in the Juan de Fuca Ridge from July to August 2011 | DOC was measured
| DO sensor |
Sulfate reduction rates at Main Endeavor grotto chimney from samples collected on RV Atlantis (AT18-08) during Jason II dives in the Juan de Fuca Ridge from July to August 2011 | DOC was measured
| DO sensor |
Survival data from static and fluctuating pCO2 x dissolved oxygen (DO) experiments on Menidia menidia | Dissolved oxygen (DO) – Optical DO probe (Hach LDO Model 2)
| Hach LDO Model 2 |
Synthesis Product for Ocean Time Series (SPOTS) |
Seabird SBE43 used for CVOO & DYFAMED
Seabird SBE 13 used for HOT
RINKOIII used for DYFAMED
| Dissolved Oxygen Sensor |
Table 1: Physical and chemical parameters during Calanus finmarchicus and Meganyctiphanes norvegica egg hatching experiments, 2011-2012 | Used to measure dissolved oxygen in the experimental tanks.
| model 55 YSI dissolved oxygen meter |
Tank conditions for pH experiments on Lophelia pertusa specimens collected in the Norwegian Skagerrak and the Gulf of Mexico (Lophelia OA project) | Measured dissolved oxygen concentrations
| Strathkelvin 782 dual oxygen meter |
Temperature data measured during two experiments testing the effects of acute and chronic thermal stress on the scleractinian coral, Stylophora pistillata | Oxygen flux in the chambers was measured at 1-s intervals using oxygen probes (FireSting O2, Pyroscience).
| FireSting O2, Pyroscience oxygen probes |
Water and oxygen metabolism flux data from two tidal creeks on Plum Island, Massachusetts during 2012. | Measured oxygen saturation, not concentration
| Oxygen saturation sensor |
Rates of photosynthesis and respiration by Ulva exposed to different average and variability of pCO2 (Seaweed OA Resilience project) | Used to measure oxygen, photosynthesis, and respiration.
http://www.qubitbiology.com/ox1lp-dissolved-oxygen/
| Qubit Systems Dissolved Oxygen package (Q-box OX1LP) |
Pencil urchin respiration rates at different temperatures from four sites in the Galápagos archipelago | | fiber-optic oxygen probe (Presens dipping probes [DP-PSt7-10-L2.5-ST10-YOP], Germany) |
Pencil urchin respiration rates at different temperatures from four sites in the Galápagos archipelago | | Presens Oxygen Meter System (OXY-10 SMA (G2) Regensburg, Germany) |
Louisiana shelf water column production and respiration measured by change in oxygen in light and dark bottle incubations during four cruises in 2017 | Concentrations of O2 were measured initially and after 24 hours using a Hach or YSI oxygen sensor and temperature probe.
| O2 probe with thermometer (Hach or YSI) |
Results from Calanus pacificus Hypoxia Laboratory Experiments from 2019-2020 (Zooplankton Swimming project) | A PreSens oxygen dipping probe was used to measure dissolved oxygen when different oxygen conditions were being created within the experimental tanks, and at the end of each experiment at the surface, upper halocine, lower halocine, and bottom of each tank.
| PreSens Oxygen Dipping Probe |
Respirometry data for pelagic crustaceans, cephalopods, and fish collected on R/V Sikuliaq cruise SKQ201701S from January to February 2017 | Pyroscience Firesting FS02-4: four-channel optical oxygen meter
| Pyroscience Firesting FS02-4 |
Respirometry data for pelagic crustaceans, cephalopods, and fish collected on R/V Sikuliaq cruise SKQ201701S from January to February 2017 | Presens Witrox 4 OX11875: four-channel optical oxygen meter
| Presens Witrox 4 OX11875 |